Elaborate HQ-A

Elaborate-Finest Space Design
Elaborate HQ-A
Ceiling:CCS-15
Car operating panel:COP-52
Handrail:SHR-4
Floor:CGS-51 (Marble/Quartz tiles)
Front wall:Ti-coated Mirror finished stainless steel
Cabin door:Matted stainless steel
Cabin:Matted stainless steel

Specification

• Landing Door

HQD-1

HQD-1

Jamb:Splay with transom (Ti-coated Mirror finished stainless steel)

Hall call panel:EOP-53 (Ti-coated Mirror finished stainless steel)

Door:Ti-coated Mirror finished stainless steel with etching

Hall indicator:FPI-51

HQD-2

HQD-2

Jamb:Splay with transom (Ti-coated Mirror finished stainless steel)

Hall call panel:EOP-53 (Mirror finished stainless steel)

Door:Mirror finished and Matted stainless steel

Hall indicator:FPI-52

HQD-3

HQD-3

Jamb:Splay with transom  (Ti-coated Mirror finished stainless steel)

Hall call panel:EOP-53 (Mirror finished stainless steel)

Door:Mirror finished stainless steel with etching

Hall indicator:FPI-53

HQD-4

HQD-4

Jamb:Splay with transom  (Ti-coated Mirror finished stainless steel)

Hall call panel:EOP-53 (Ti-coated Mirror finished stainless steel)

Door:Ti-coated Mirror finished stainless steel with etching

Hall indicator:FPI-54

• Floor Plattern Marble/Quartz tiles

CGS51

CGS51

CGS52

CGS52

CGS53

CGS53

 CGS54

CGS54

CGS55

CGS55

CGS56

CGS56

 

 

• Cabin and Door

鏡面不銹鋼

Mirror finished stainless steel             

霧面不銹鋼

Matted surface stainless steel        

髮紋不銹鋼

Hairline finished stainless steel  

鍍鈦鏡面蝕刻

Ti-coated Mirror finished (etching)

精緻烤漆

Baked finished

鍍鈦不銹鋼

Ti-coated stainless steel

 

 

• Hall Indicator

FPI-51

FPI-52

FPI-53

FPI-54

• Operating Panels

Car Operating Panels

COP-52  Integrated operating panels touch button (Elaborate series)                         

 

Car Operating Panels

COP-62 Integrated operating panels puch button (Elaborate series)

Hall Operating 

EOP-53 Touch button 

 

 

 

 

 

Hall Operating 

EOP-63 Puch button 

 

 

 

 

 

• Options

• LED Lighting System

The brightness of light can be changed with different operations of elevators, and can match different festivals, situations and decorations with changes of color and flashing lights. It provides passengers with a more pleasurable ride and increases the vitality of buildings. Besides, clients can choose a variety of colors according to different situations.

• Specialized LCD

Full-colored 10.2 inches LCD can be set into the cabin to increase the enjoyment of the ride.

 液晶螢幕  液晶螢幕                                                                                                                                                                                                                                                                         

Access Control System

Sensor chips:Identify the authority by sensor card.

Swipe enter PIN:To swipe or enter PIN number can be chosen to identify the authorized personnel.

Fingerprint Verification:Fingerprint verification system is the most scientific and effective system to recognize an individual's identity, which can prevent mishaps from damaged or missing cards or forgetting passwords.                                                                                                                                                                                                                                                                                                                                                                                                                                             

 Standard and Optional Function List

Feature Bracket Function Elegant Elaborate Panoramic
Space and Elasticity Door Type Two-panel center opening automatic door (CO)
Two-panel slide opening automatic door (2S) - -
Four-panel center opening automatic door (4C) - ● 
Car Operation Panel Hairline finshed stainless steel -
Integrate -
Convenience Doorsill dirt discharge hole
Socket for car cleaning purpose
Environment and Security Loading Overload limited function
Communication Intercom between cabin and hall (control room)
Phone (own number required) ▲  ▲ 
Anti Door-clamp   Single safety edge
Double safety edge
Ultrasonic door sensor ▲   
Door sensor self-diagnosis ● 
Safety light curtain device ▲ 
Damage Protection Earthquake control operation ▲   
Emergency lighting
Breakdown operation device
Wet hoistway warning and restrain
Safety arrival device (designated floor)
Fire-man control service
Fire emergency return ▲  ▲  ▲ 
Emergency power operation ▲  ▲  ▲ 
Security Fingerprint analyze system ▲  ▲  ▲ 
Sensor control system ▲  ▲  ▲ 
Guard calling system (special floor) ▲  ▲  ▲ 
Password car calling exclusive ▲  ▲  ▲ 
Unusual Passenger activity sensor ▲  ▲  ▲ 
Welfare Device (for Elegant series only) Handrail ▲  ▲  ▲ 
Mirror and convex mirror ▲  ▲  ▲ 
Braille mirror ▲  ▲  ▲ 
Specialized vice-operating panel ▲  ▲  ▲ 
Intelligence & Technology Hall Calling Type Selective collective operation
Up or down collective operation ▲  ▲  ▲ 
Group supervisory operation system ▲  ▲  ▲ 
False call canceling
Humanity Mischievous call canceling function
Full-load express function
Automatic door-open time adjustment ▲ 
Extended door-open button ▲  ▲  ▲ 
Voice synthesizer system ▲  ▲  ▲ 
VIP Operation Control lock ▲  ▲  ▲ 
Designated individual operation in multi-elevator
Authorized operation ▲  ▲  ▲ 
Hall call lock
Non-stop floor service ▲  ▲  ▲ 
Self-Detective & Recovery Repeated door-close (obstacle remove)
Auto-landing after power recovery
Energy-Saving Car fan automatic shut-off
Car light automatic shut-off
Elevator Indicator Landing indicator (Elaborate series) ▲ 
Car& Hall dot matrix type indicator ●  - ●(Depends on the type)
Car& Hall single color LCD indicator - ●  ● (Depends on the type)
Car& Hall full color LCD indicator ▲  ▲  ▲ 
Elevator Monitor Central monitor control ▲  ▲  ▲ 
Remote monitor control ▲  ▲  ▲ 
Wide-angle CCTV ▲  ▲  ▲ 
      ●Standard option ▲Option for additional charges

 

Specification
Model
Passenger
(Capacity) 
Speed
m/min
Hoistway
B1xB2
Cabin
A1xA2xH1
Door
Type
Opening
WxH2
Overhead
OH≥
PIT Reaction(㎏)
R1 R2 R3 R4 R5 R6
SCP -08 8人
(550㎏)
60 2250x1650 1400x1030x2300 CO 800x2100 Over 4000 1600 4510 3610 1580 1780 1170 1700
90 Over 4400 1850 6760 5420
SCP -09 9人
(600㎏)
60 2250x1700 1400x1100x2300 CO 800x2100 Over 4000 1600 5000 4020 1720 2030 1340 1850
90 Over 4400 1850 7500 6030
SCP -10 10人
(700㎏)
60 2250x1750 1400x1250x2300 CO 800x2100 Over 4000 1600 5330 4180 1100 2430 1210 1510
90 Over 4400 1850 7990 6270
105 Over 4800 2150 11980 9410
120 15970 12540
SCP -11 11人
(750㎏)
60 2250x1800 1400x1350x2300 CO 800x2100 Over 4000 1600 5650 4430 1210 2570 1270 1620
90 Over 4400 1850 8480 6640
105 900x2100 Over 4800 2150 12710 9960
120 16950 13280
SCP -12 12人
(800㎏)
60 2250x1850 1400x1400x2300 CO 900x2100 Over 4000 1600 5980 4670 1290 2780 1300 1660
90 Over 4400 1850 8970 7010
105 Over 4800 2150 13450 10510
120 17930 14010
SCP -13 13人
(900㎏)
60 2450x1800 1600x1350x2300 CO 900x2100 Over 4000 1600 6630 5160 1420 3130 1490 1780
90 Over 4400 1850 9950 7740
105 4C 1200x2100 Over 4800 2150 14920 11610 1430 3130 1460 1810
120 19890 15480
SCP -15 15人
(1000㎏)
60 2450x1900 1600x1500x2300 CO 1000x2100 Over 4000 1600 7120 5490 1570 3330 1570 1930
90 Over 4400 1850 10680 8230
105 2450x1950 4C 1200x2100 Over 4800 2150 16020 12340 1580 3330 1540 1960
120 21350 16460
SCP -17 17人
(1150㎏)
60 2450x2000 1600x1600x2500 CO 1000x2100 Over 4500 1600 7770 5900 1740 3590 1690 2110
90 Over 4700 1850 11660 8840
105 2450x2050 4C 1200x2100 Over 5600 2150 17480 13260 1750 3590 1660 2140
120 22310 17680
SCP -20 20人
(1350㎏)
60 2650x2100 1800x1700x2500 CO 1000x2300 Over 5600 1600 8750 6550 1900 4200 1880 2230
90 1850 13130 9820
105 2650x2150 4C 1400x2300 2150 19690 14730 1920 4320 1850 2130
120 26250 19640
SCP -24 24人
(1600㎏)
60 2850x2150 2000x1750x2500 CO 1000x2300 Over 5600 1600 10220 7610 1680 4930 2190 2580
90 1850 15330 11410
105 2850x2200 4C 1400x2300 2150 22990 17120 1965 3265 4108 6522
120 30650 22820
Specification
Model
Passenger
(Capacity)
Speed
m/min
Hoistway
B1xB2
Cabin
A1xA2xH1
Door
Type
Opening
WxH2
Overhead
OH≥
PIT Reaction(㎏)
R1 R2 R3 R4 R5 R6
SCB -11 11人
(750㎏)
60 2300x2800 1300x2300x2300 2S 1100x2100 Over 4000 1600 6790 5570 1400 3160 1370 2230
90 Over 4500 1850 10190 8350
SCB -15 15人
(1000㎏)
60 2500x3000 1500x2500x2300 2S 1100x2100 Over 4500 1600 8260 6630 1680 3980 1650 2550
90 Over 4700 1850 12390 9950
Machine room-less elevators are suitable for less than 12 stops or total travel less than 40M.

 

 

Specification
Model
Passenger
(Capacity)
Speed
m/min
Hoistway
B1xB2
Cabin
A1xA2xH1
Door
Type
Opening
WxH2
Overhead
OH≥
PIT Machine Room Reaction(㎏)
MAxMB MAxMB R1 R2 R3 R4
SAP -08 8人
(550㎏)
60 1800x1630 1400x1030x2300 CO 800x2100 Over 4450 1550 2400x3300 2050 4500 3600 3200 2100
90 1850x1680 Over 4650 4850 3000x3400 2250 6750 5400
SAP -09 9人
(600㎏)
60 1850x1700 1400x1100x2300 CO 800x2100 Over 4450 1550 2400x3400 2050 4800 3800 3350 2200
90 1850x1750 Over 4650 1850 3000x3600 2250 7200 5700
105 Over 4850 2150 8400 6650
120 12567 9967
SAP -10 10人
(700㎏)
60 1800x1850 1400x1250x2300 CO 800x2100 Over 4450 1550 2400x3600 2050 5300 4150 3700 2350
90 1850x1900 Over 4650 1850 3000x3600 2250 7950 6225
105 Over 4850 2150 9275 7250
120 13867 10833
SAP -11 11人
(750㎏)
60 1800x1950 1400x1350x2300 CO 800x2100 Over 4450 1550 2400x3700 2050 5600 4400 4350 2500?
90 1950x2000 Over 4650 1850 3000x3700 2250 8400 6600
105 900x2100 9800 7700 5100 3950
120 Over 4850 2150 14733 11483
SAP -12 12人
(800㎏)
60 1800x2000 1400x1400x2300 CO 800x2100 Over 4450 1500 2200x4000 2050 6000 4600 4400 2650
90 1950x2050 Over 4650 1850 3000x4000 2250 9000 6900 5100 3950
105 900x2100 Over 4850 2150 10500 8050
120 15600 12133
SAP -13 13人
(900㎏)
60 2200x2100 1600x1350x2300 CO 1000x2100 Over 4450 1550 2800x3800 2050 6600 5100 4800 2950
90 Over 4650 1850 3200x3600 2250 9900 7650
105 4C 1200x2100 Over 4850 2150 11550 8900 5850 4550
120 17333 13433
SAP -15 15人
(1000㎏)
60 2200x2250 1600x1500x2500 CO 1000x2300 Over 4450 1550 2800x4000 2050 7100 5500 5200 3200
90 Over 4650 1850 3200x4100 2250 10650 8250
105 4C 1200x2300 Over 4850 2150 12425 9600 6200 4800
120 18633 14300
SAP -17 17人
(1150㎏)
60 2200x2350 1600x1600x2500 CO 1000x2300 Over 4450 1550 3200x4200 2050 7800 5900 7050 4200
90 Over 4650 1850 2250 11700 8850
105 4C 1200x2300 Over 4850 2150 13650 10325 7450 4400
120 20367 15383
SAP -20 20人
(1350㎏)
60 2300x2450 1800x1700x2500 CO 1000x2300 Over 4450 1550 3400x4300 2050 8800 6600 8600 4900
90 Over 4650 1850 2250 13200 9900
105 2500x2500 4C 1400x2300 Over 4850 2150 15400 11550 8900 5050
120 22967 17117
SAP -24 24人
(1600㎏)
60 2500x2500 2000x1750x2500 CO 1000x2300 Over 4450 1550 3600x4400 2050 9950 7300 9100 4500
90 Over 4650 1850 2250 14925 10950
105 2600x2600 4C 1400x2300 Over 4850 2150 17400 12775 9500 5100
120 26000 19067
Specification
Model
Passenger
(Capacity)
Speed
m/min
Hoistway
B1xB2
Cabin
A1xA2xH1
Door
Type
Opening
WxH2
Overhead
OH≥
PIT Reaction(㎏)
R1 R2 R3 R4 R5 R6
SAB -11 11人
(750㎏)
60 2200x2800 1300x2300x2300 2S 1100x2100 Over 4000 1600 3853 3003 1114 1751 2858 3460
90 Over 4500 1850 4420 3445
SAB -15 15人
(1000㎏)
60 2400x3000 1500x2500x2300 2S 1100x2100 Over 4500 1600 4873 3740 1330 2221 2758 4453
90 Over 4700 1850 5590 4290
Machine room elevators suitable for less than 32 stops.
Elegant Series: less than 15 passengers; Elaborate Series: more than 15 passengers.

 • After-sale service
Please contact our local agent in your region for after-sale services.
1. 24-hour emergency repair service all year round.
2. Regular maintenance and inspection.
3. Provide the spare parts from LIWIN and upgrade the program.


Shpuld the elevators be out of order or there is a power failure:
    A . Emergency lighting allows passengers to recognize the buttons clearly and relieve nervousness.
    B . The air is ventilated by ventilating hole in breakdown.
    C . Emergency exit. (CNS Regulations Taiwan)
    D . When the UPS (optional) isinstalled, passengers should wait patiently for the system to turn on, instead of forcing the elevator to open, which may cause technical malfunction or user injury.
    E. Communicate with outside people through the intercom in the cabin, for example, the administration room.
    F . Contact service technicians of local agent directly.


※The elevator is prohibited from operating during an earthquake,flood or fire.