Diana Series

Because of an aging society and strict government regulations on Floor Area Ratio , modern consumers have higher expectations for the quality of their lives. Therefore, LIWIN launched New Generation SWEET HOME ELEVATOR to build a barrier-free living space and meet the needs of all family members. Furthermore, the elegant design is coordinated with your elaborate interior design, which increases family interaction and
communication.
New Generation SWEET HOME ELEVATOR can be applied extensively with its high speed, simple operation, full function, saving space, varied regulations, elegant design, elaborate quality and more.
It is worthy of your choice Let New Generation SWEET HOME ELEVATOR create a happy and comfortable living space for you and your family.

Video

Specification

Series Diana Series Venus Series
Model DAP-052S DAP-062S VSP-054C VSP-064C
Drive type Geared Traction Machine by Electric Motor
Controller Variable Voltage, Variable Frequency (VVVF)
Operation Collective Operation for Sweet Home Elevator
Speed 30.45 m/min(0.5.0.75 m/sec) 30.45 m/min(0.5.0.75 m/sec)
Capacity 5 Persons 6 Persons 5 Persons 6 Persons
Load 380 kgs 450 kgs 385 kgs 450 kgs
Cabin Width x Depth x Height Width x Depth x Height
850×1200×2200mm 900×1200×2200mm 1300×800×2200mm 1300×900×2200mm
Door
type
Two-panel side opening automatic door Four-panel center opening automatic door
Opening
dimension
Width x Height Width x Height
800mm×2000mm 800mm×2000mm 1000mm×2000mm 1000mm×2000mm
Power
supply
1 φ AC 220V 50/60HZ 1 φ AC 220V 50/60HZ
Motor 5HP 5HP
Travel Below 6 floors(Below 20m)
Overhead Over 3700mm
Pit depth Over 1200mm
Safety
device
CNS-10594 (Taiwan)
     
● Please contact our sales accosiates if specially design or materials are needed.

 

Explain the optional function
Standard option Option for additional charges

Automatic energy-saving function
If the waiting time is exceeding the setting time, the lighting and the fan of the cabin will turn off automatically; while someone press the button, the cabin will re-start to save the electricity.

Emergency Lighting
In case of blackout, the emergency lighting device (5W) inside the cabin will activate automatically. The emergency lighting can last up to thirty minutes.                                           

Special Power requirement
Single phase AC 110V or other special power supply can be applied on request.                                                                                                                                          

Telephone
It can set up the outside connection and contact with outsides in emergency. The telephone numbers will be provided by owner.

Floor Indicator
Cabin/ Hall operating panels will display the elevator floor location.                                                                                                                                                              

Earthquake control operation
When an earthquake occurs, the elevator will operate to the nearest floor for passengers to escape.                                            

Emergency calling button
While in the situation of power-cut or emergency, press the ring button to make the alarm signal for help to the outsides.                                                                                                                                                                                                       

Door open, close button
Press the “open”button, the door will be opened again; press the “close”button, the door can be closed earlier to eliminate the waiting time.                                              

 

Photo Sensor Device
For the wheelchair users, the photo sensor device is installed at the cabin door. Door closing function will delay if sensor light beam is blocked. (the photo sensor device must be added to the door safety edge.)
Extend the door opening function
Keep to press the button “open door”over 3 seconds in the operator of the cabin, the door can last to open for three minutes (the time depends on the customer’s requirement) to facilitate the wheelchair entering the cabin.                                                                     
Overload Limit
When the loading detector detects an excess of weight, cabin door will stay open and the elevator is prevented from moving. Meanwhile, the alarm will sound until the load is reduced. The elevator will then resume to normal operation. 

Safety Light Curtain Device
Additional to the above functions, we can substitute Safety light curtain device to safety edge devise. Safety light curtain device will ensure passenger safety. (It is applicable to Venus series.)            

Passenger priority function
If the passenger keeps to press the “closing”button, the elevator will arrive the appointed floor and temporarily neglect the other’s floor calling. 
Cancellation
By rapidly pressing the floor number button twice, the passenger can cancel the registered floor.                                      

Monitor
Camera can be added and connected to the control center at the customer’s request.

 

Reverse opening of the door
In the process of closing door, if the resistance force is bigger than torque force of the motor, the door will stop closing and re-open by the double safety edge device.

                                                                                                                                       

Double safety edge devise
When resistance is confronted during door closing, the safety edge devise will be activated to stop the door from closing. (One side safety edge devise is applicable to Diana series, and double safety edge devise is applicable to Venus series.) 

Breakdown operation devise
In case of power outage, the elevator will operate to the nearest floor for passengers to escape; after all the people run away, and then the elevator turn off.                                        

                                                            

 

COLOR CODES

Ceiling:SEC-001

Cabin:DAP-SEP-B

Door:SED-104B

Floor:SE-507

COLOR CODES

Ceiling:SEC-002

Cabin:DAP-SEP-C

Door:SED-105C

Floor:SE-509

COLOR CODES

Ceiling:SEC-002

Cabin:DAP-SEP-B

Door:SED-102A

Floor:SE-536

COLOR CODES

Ceiling:SEC-003

Cabin:DAP-SEP-D

Door:SED-103D

Floor:SE-506

Cabin door

SED-102A

SED-102B

SED-102C

SED-102D

SED-103A

SED-103B

SED-103C

SED-103D

SED-104A

SED-104B

SED-104C

SED-104D

SED-105A

SED-105B

SED-105C

SED-105D

Diana series

Top floor
(Maintenance door attached)Standard floor

Venus series

Top floor
(Maintenance door attached)

Standard floor

Decorative PVC Laminated Steel Plate Car Operating Panel

 SEP-A

SEP-B

 

COP-21 Walnut grain face plate

 SEP-C

 SEP-D

 

COP-22 Stainless Steel face plate

Hand rail

PVC Plastic Tiles (Removable carpet is available(Optional))

Wooden hand rail

SE-507

SE-506

 

Stainless Steel hand rail

 

SE-509

SE-536

Hall Call Panel

 

Walnut grain face plate

EOP-31

 

Stainless Steel face plate

EOP-41

 

Walnut grain face plate

EOP-32

 

Stainless Steel face plate

EOP-42

Repair Lock (Authorities only)

The repair lock is installed in the landing door to allow the technicians access if an emergency / breakdown.

 

Control Lock

The client can set control locks on designated floors for privacy.

                                                    

 

Wheel Chair Access

The access may vary according to the different cabin models. If a cabin is not deep enough, the wheel chairs may be rotated to enter the cabin.

Normal wheel chair
width : 61cm.  length : 41 ~ 43cm.

           

Carrying Articles

When carrying articles like the shopping, furniture, or living devices, you can make use of the wide opening doors and height of the cabin to arrange them.             

 

               

 

REQUIRE FACILITATING PROJECTS

The following are other facilitating projects required and provided by proprietor and other parties to ensure product quality and installation safety.
1. Provide power source with grounding for the elevator (voltage variation should be less than 5% ).
2. If outside communication is needed, please apply for the telephone line to connect to the control room.
3. Provide accurate dimensions for the hoistway (vertical tolerance within 3cm; horizontal tolerance less than 10cm ).
4.Please provide the level line of completed face of every landing door.
5. According to the layout provided by LIWIN, reserve the space for landing door and maintenance door. Upon completion of installation, cement backfill will be neccssary.
6. Waterproof and drainage works in the pit shall be finished before installation.
7. Pipes or cables are not allowed inside the hoistway.
8. If the elevator stops at the top floor, rain shield shall be installed to protect from rain.
9. Please offer passageways to carry elevator equipment and storage space as well.
10. Provide temporary power source for installing and commissioning.
11. Provide safety railing or fences for landing door and other openings during installation.

Q & A